This benchtop class B autoclave combines compact design with high performance, reliability and safety.
- Model : ST-BA18B; ST-BA24B; ST-BA45B
- Volume : 18L; 24L; 45L
- Design Temperature : 139℃
- Rated Working Pressure : 0.22Mpa
This benchtop class B autoclave combines compact design with high performance, reliability and safety.
The 8-litre, 12-litre and 45-litre table-top autoclaves feature a class B pre-vacuum and comply with the European standard EN13060. Requiring very little space, this class B autoclave is the ideal solution for small businesses such as tattooing, podiatry consultants, beauty salons, veterinarians and laboratories.
Model | ST-BA18B | ST-BA24B | ST-BA45B |
Volume | 18L | 24L | 45L |
Power | 2.2kw | 2.2kw | 3.5kw |
Voltage | 220V110V; 50/60Hz | ||
Design Pressure | 0.25Mpa | ||
Design Temperature | 139℃ | ||
Rated Working Pressure | 0.22Mpa | ||
Rated Working Temperature | 134℃ | ||
Chamber Volume | Ø250×370 | Ø250×470 | Ø316×615 |
Sizes(WxDxH)(mm) | 620x505x450 | 710x505x450 | 870x657x575 |
Shipping Size (WxDxH)(mm) | 670x560x510 | 760x560x510 | 980x750x630 |
N.W./G.W. (kg) | 53/62 | 58/65 | 105/142 |
The overall design of the benchtop class B autoclave reflects simplicity and practicality, providing users with a comfortable and convenient operating experience.
Clean appearance, smooth lines, touch screen control panel is convenient for users to set and monitor the sterilisation process.
The shelves are made of high quality stainless steel, sturdy and durable, and can accommodate multiple instruments or items to be sterilised.
The spacious design of the chamber ensures that steam penetrates evenly to every corner, ensuring the complete sterilisation of items.
What is B type of sterilization?
Type B sterilization refers to a classification of sterilization methods that are capable of effectively sterilizing all types of medical devices, including hollow, porous, and solid items, ensuring the complete elimination of all forms of microbial life, including bacterial spores.
Difference between B class and N class autoclave?
Class B autoclaves are capable of sterilizing all types of instruments including hollow, porous, and solid items, while Class N autoclaves are limited in their ability to sterilize hollow and porous items due to their vacuum capabilities.
What is the B type autoclave sterilisation process?
Type B autoclaves start by evacuating nearly all air from both the chamber and the load. Following this, they introduce short bursts of steam until the chamber reaches the necessary pressure and temperature for sterilization to commence. These conditions are maintained throughout the sterilization process for the specified holding time.
How is a B type autoclave maintained?
Although the appliance’s quality ensures its performance, adhering strictly to the maintenance schedule is crucial. Daily, clean the external surfaces, door, and its seal. Weekly, disinfect the water tank and thoroughly clean the internal filters.