Ductless Fume Hood

Standard ductless fume hood is an innovative and purpose driven product for the research and healthcare industries.

  • Model : FMH-DL-LP800
  • Filter : 1pcs Pre-filter, Polyester fiber,washable; 1pcs Active Carbon filter
  • Max. Opening : 690mm
  • Air-velocity Range : 0.4-0.6m/s, speed adjustable
  • Sound Emission : ≤50dB(A)
  • External Size (WxDxH)(mm) : 800x620x1130 (Without Base Stand)
Category:

Description

This kind of fume hood employs HEPA filtration to safeguard laboratory staff from particles. Additionally, with optional carbon or chemical filters, it can also shield them from toxic chemical fumes and odors. Renowned for its plug-and-play functionality and portability, the ductless fume hood ensures easy installation and uninterrupted lab work.

Ductless Fume Hood Feature:

Powerful filtration system can be configured with HEPA filters and chemical filters according to customer requirements, effectively filtering and removing harmful substances to ensure a safe operating environment and protect personnel from harm.

Easy to operate, and fume hood equipped with a 7-inch LCD color touchscreen, it displays real-time parameters such as air velocity, VOC concentration, temperature and humidity, and filter lifetime. This achieves excellent human-machine interaction.

Ductless Fume Hood Specifications:

Model FMH-DL-LP800
External Size (WxDxH)(mm) 800x620x1130 (Without Base Stand)
800x620x1800 (With Base Stand)
Internal Size (WxDxH)(mm) 780x540x775
Max.Opening 650mm
Operation Surface Height 690mm
Control System 7-inch color touch screen,real-time display air velocity, VOC concentration, temperature and humidity, and filter life time etc
Airflow System Airflow Velocity 0.4-0.6m/s, speed adjustable
Air filtration System Filter 1pcs Pre-filter, Polyester fiber,washable
1pcs Active Carbon filter
Cabinet Construction Main Body Electro-galvanized steel with antimicrobial Powder Coating
Work Surface 304 Stainless Steel, Max.loading of worksurface: 70kg
Front Window Manual acrylic window
Electrical System LED Lamp 16W×1
Blower DC Centrifugal blower, adjustable speed, low noise
Consumption 60W
Power Supply AC220V±10%, 50/60HZ; 110V±10%, 60Hz
Sound Emission ≤50dB(A)
Standard Accessory 1. Active Carbon Filter×1; 2. Pre-Filterr×1; 3. LED Lamp×1
Optional Accessory 1. Base Stand; 2. Base Cabinet; 3. HEPA Filter; 4. Chemical filter; 5. Upgraded LED Lamp
Net Weight 96kg
Gross Weight 138kg
Shipping Size (WxDxH)(mm) 1160×840×1320
Shipping Volume 1.3m3

Advantages of Ductless Fume Hood:

  1. Three-sided acrylic transparent observation window for multi-angle viewing.
  2. Low noise design with high-quality DC centrifugal blower for quiet operation.
  3. Memory function for power outage protection.
  4. Audio and visual alarms for filter life and VOC concentration.
  5. Easy-to-clean brushed stainless steel work surface.
  6. Available in various sizes for benchtop or mobile base use (2 to 6 feet).

What is a ductless fume hood used for?

The primary purpose of a ductless fume hood is to remove contaminants present in the air of a laboratory or workspace. This includes substances like chemicals, gases, odors, corrosive, or flammable materials.

  1. Handling of chemical reagent vapours and gases in chemical laboratories.
  2. Hazardous gases and particles from biological samples are handled in biological laboratories.
  3. Hazardous chemicals from drug synthesis are handled in pharmaceutical research.

Ductless Fume Hood Display:

The simple control panel and compact dimensions make it suitable for a wide range of laboratory environments.

Ductless Fume Hood

Ductless Fume Hood PACKAGING

Labpeak’s ductless fume hood is packed and shipped in a sturdy timber box with cardboard and foam padding to ensure safe delivery to its destination.

WHY Labpeak

  1. 18 Months Limited Warranty
  2. CE & FDA Standards
  3. 1-2 Days Handling and 7-30 Days Shipping

FAQ

What is ductless fume hood?

A ductless fume hood is a type of laboratory ventilation system that captures and filters harmful fumes and particulates using filtration systems instead of venting them outside through ductwork.

Difference between ductless and ducted fume hoods?

Ducted fume hoods can be filtered or unfiltered depending on the design and application. Ductless fume hoods contain filters which clean contaminated air and recirculate it directly back into the laboratory. No additional ductwork is required to exhaust air to the outside.

Are ductless fume hoods safe?

Ductless fume hoods protect the individuals who use them and people working in the same area from fumes, vapors, and particles that can result in injuries and possibly even death. If the intake airflow is not within a specified range, hazardous materials may flow out of the fume hood and cause harm.

Are ductless fume hoods effective?
While ductless fume hoods offer cost-efficiency, ease of installation, and eliminate the need for ductwork, they may not be suitable for all scenarios compared to other types of chemical fume hoods.

Title

CONTACT INFO

Xuegu Huigu Science and Technology Park, Xiqing District, Tianjin

Phone: +86-531-82893797

Go to Top