Description
The ST-BVA series pulse vacuum autoclave utilizes saturated steam for thorough sterilization. Employing pulsating vacuum technology, steam deeply permeates article surfaces, effectively eliminating all microorganisms and spores. This method, combining high pressure and high-temperature saturated steam, offers potent physical sterilization.
Cold air’s impact on temperature is mitigated by pulsating vacuum exhaust, ensuring comprehensive sterilization through vacuum dehumidification and jacket drying processes. This horizontal pulse vacuum sterilizer finds applications in pharmaceutical and biological engineering, medical health, laboratory animals, and more.
It excels in sterilizing utensils, aseptic clothing, rubber plugs, aluminum caps, raw materials, filters, media, and various other items.
Horizontal Pulse Vacuum Autoclave Features:
- Anti-Pinch hand function, ensuring user safety during operation.
- The pulse vacuum autoclave incorporates a double-door channel design featuring a powerful pressure safety interlock and temperature safety interlock on the liquid process door, ensuring comprehensive operational safety.
- Vacuum autoclave is quipped with a high-efficiency automatic sealing ring, the sterilizer boasts outstanding sealing performance. With a service life of up to 1500 times.
- The main structure adopts a european ring reinforcement jacket structure, ensuring durability and reliability.
- Featuring a programmable controller PLC and color touch screen, the vacuum autoclave offers intuitive operation and control for enhanced user experience.
Horizontal Pulse Vacuum Autoclave Specifications:
Model |
ST-BVA250PV |
ST-BVA360PV |
ST-BVA600PV |
ST-BVA800PV |
ST-BVA1000PV |
ST-BVA1200PV |
ST-BVA1500PV |
ST-BVA2000PV |
ST-BVA2500PV |
ST-BVA3000PV |
ST-BVA4000PV |
ST-BVA6000PV |
Capacity(L) |
255 |
360 |
600 |
800 |
1000 |
1200 |
1500 |
2000 |
2500 |
3000 |
4000 |
6000 |
Interior Design Pressure |
-0.1~03MPa |
Jacket Design Pressure |
0.3MPa |
Design Temperature |
150℃ |
Max Working Temperature |
139℃ |
Max Working Pressure |
0.25MPa |
Vacuum Leakage Rate |
≤0.13KPa/min |
Final Vacuum |
-96KPa |
Opening Pressure of the Inner Chamber Safety Valve |
0.28MPa |
Jacket Safety Valve Opening Pressure |
0.28MPa |
Sterilization Temperature Control Precision |
0-2℃ |
Temperature Uniformity |
±0.5℃ |
Negative Pressure Pulsating Vacuum Negative Value and Number |
Amplitude -80~0KPa, frequency 1~99 |
Number of Pulsations Across Pressure |
Amplitude -80~80KPa, frequency 1 |
Number of Positive Pressure Pulsations |
1~3 |
Inner Tank Size (WxH)(mm) |
550×550 |
610×610 |
610×910 |
610×910 |
610×910 |
680×1180 |
680×1180 |
900×1380 |
900×1380 |
900×1380 |
900×1380 |
900×1380 |
Depth |
850 |
1000 |
1200 |
1500 |
1800 |
1500 |
1850 |
1620 |
2050 |
2400 |
3200 |
4800 |
Overall Size (LxWxH)(mm) |
1150×1280
x1800 |
1300×1350
x1850 |
1500×1440
x1900 |
1800×1440
x1900 |
2100×1440
x1900 |
1800×1480
x2000 |
2100×1480
x2000 |
1970×1750
x2200 |
2350×1750
x2200 |
2700×1750
x2200 |
3500×1750
x2200 |
5400×1750
x2200 |
Weight (kg) |
750 |
850 |
1250 |
1350 |
1550 |
1650 |
1850 |
2300 |
2700 |
3500 |
3500 |
6200 |
Gas Consumption (Kg/c) |
18 |
22 |
35 |
47 |
55 |
65 |
80 |
106 |
132 |
132 |
132 |
132 |
Water Consumption (Kg/c) |
120 |
180 |
320 |
400 |
500 |
600 |
750 |
1000 |
1250 |
1250 |
1250 |
1250 |
Power Supply |
380V, 50Hz |
380V, 50Hz |
380V, 50Hz |
380V, 50Hz |
380V,50Hz |
380V,50Hz |
380V,50Hz |
380V,50Hz |
380V,50Hz |
380V,50Hz |
380V,50Hz |
380V,50Hz |
Consumption |
2KW+(24KW) |
2KW+(30KW) |
3KW+(48KW) |
3.5KW+(54KW) |
3.5KW |
3.5KW |
4KW |
4.5KW |
6KW |
8KW |
8KW |
12KW |
Advantage of Horizontal Pulse Vacuum Autoclave:
- Offers a wide range of customizable procedures for various items such as aseptic clothing, utensils, rubber, liquids, media, waste, and more. Includes professional tests like BD test and vacuum leakage test to meet diverse needs.
- Horizontal pulse vacuum is equipped with a built-in micro-needle printer and paperless recorder for easy recording and tracking of sterilization processes.
- Features an automatic drainage device, including optional jacket automatic control drainage, to ensure steam saturation. Automatic detection of jacket and inner chamber temperature and pressure for efficient drainage.
- Optional remote monitoring and maintenance module available. Optional water-saving and noise reduction system for enhanced efficiency and comfort.
Horizontal Pulse Vacuum Autoclave Packing:
- Edges protected with foam and fixed with protective film.
- All covered with strong and hard protective film.
- Plywood packaging and steel banded external fixing boxes.
- Complete packing in normal containers or frame containers.
WHY Labpeak
- 24 Months Limited Warranty
- Help meet CE quality assurance guidelines
- 1-2 Days Handling and 7-30 Days Shipping
FAQ
What is a pulse vacuum autoclave?
The pulse vacuum steam autoclave offers steam sterilization for a wide range of items including biological products, instruments, tools, dressings, and sterile clothes using pulse vacuum technology.
What is the principle of pulse vacuum autoclave?
The pulse vacuum sterilizer operates by alternating cycles of vacuum and pressure to create a pulsating environment within the sterilization chamber. This pulsating action helps to penetrate sterilizing agents such as steam into the surfaces of the items being sterilized, ensuring thorough sterilization even in hard-to-reach areas.
Difference between vacuum and non vacuum autoclave?
The main difference between vacuum and non-vacuum autoclaves lies in their sterilization processes. Vacuum autoclaves use vacuum technology to remove air from the sterilization chamber before introducing steam, facilitating thorough sterilization of porous materials and complex instruments. Non-vacuum autoclaves rely solely on steam for sterilization and are suitable for simpler sterilization tasks where air removal is not critical.
Get Social