Horizontal Pulse Vacuum Autoclave, Motor Hinge Door

  • Model : LST-PBA650PV; LST-PBA800PV; LST-PBA1000PV; LST-PBA1200PV; LST-PBA1500PV;
  • Volume(L) : 650 / 800 / 1000 / 1200 / 1500
  • Chamber Design Pressure : 0.3MPa
  • Generator Design Pressure : 1.0MPa
  • Design Temperaure : 150℃
Category:

Description

Horizontal Pulse Vacuum Autoclave Feature:

  1. Motorized chain-driven sliding door lifts up and down.
  2. Double door interlock, including liquid pressure temperature safety interlock.
  3. Inflatable sealing ring, wear-resistant silicone, life 1500 times.
  4. Rectangular main structure, no flange European style reinforcement design.
  5. Siemens PLC control, touch screen display full automation.
  6. IOT remote monitoring and maintenance, support real-time data, troubleshooting, remote upgrade.
  7. Negative pressure, cross and positive pressure pulsation, air exclusion rate >99.99%.
  8. Flash vacuum drying, fabric drying rate <0.6%, apparatus <0.1%.
  9. Built-in printer prints data in real time, suitable for pharmaceutical customers.
  10. Sanitary stainless steel piping, using German-made control valve and water ring vacuum pump.
  11. Supply system detection alarm, automatically prevent program startup failure.
  12. Automatic drainage temperature control, drainage temperature <60℃.

Horizontal Pulse Vacuum Autoclave Specifications:

Model LST-PBA650PV LST-PBA800PV LST-PBA1000PV LST-PBA1200PV LST-PBA1500PV
Chamber Size (ØxL) (mm) 610×910×1200 610×910×1500 610×910×1800 680×1180×1500 680×1180×1850
Volume(L) 650 800 1000 1200 1500
Overall Sizes (WxDxH)(mm) 1500×1350×1900 1800×1350×1900 2100×1350×1900 1800×1420×2000 2100×1420×2000
Weight (kg) 1250 1350 1550 1650 1850
Steam Consumption (KG/C) 35 47 55 65 80
Water Consumption (KG) 320 400 500 600 750
Power 380V, 50Hz
3KW+(36KW)
380V, 50Hz 3.5KW+(48KW) 380V, 50Hz 3.5KW+(54KW) 380V, 50Hz 3.5KW+(72KW) 380V, 50Hz
4KW+(90KW)
N.W. (kg) –  1350 1550 1650 1850
Chamber Design Pressure 0.3MPa
Generator Design Pressure 1.0MPa
Design Temperaure 150℃
Maximum Operating Temperature 139℃
Maximum Operating Pressure 0.25MPa
Chamber Relief Valve 0.28MPa
Jacket Relief Valve 0.28MPa
Accuracy of Pressure 0.1KPa
Sterilization Temperature Control Accuracy ±1℃
Temperature Uniformity ±1℃
Negative Pressure Pulsating Vacuum -80~0KPa
Across the Pressure Pulsation -80~80KPa
Positive Pressure Pulse 0~9 times
Maximum Vacuum -96KPa